Intelligent liquid turbine flowmeter

Model: WCFM300 series
  • Product Introduction
The WCFM300 series intelligent liquid turbine flowmeter has absorbed advanced technologies from domestic and foreign flow meters, and has been optimized for design. It has the characteristics of simple structure, lightweight, high accuracy, good repeatability, sensitive response, and easy installation and maintenance. It is a speed based flow meter. Used to measure the volumetric flow rate of a liquid filled in a closed pipeline and flowing continuously. Suitable for measuring clean and low viscosity liquids. Widely used in industries such as petroleum, chemical, metallurgy, scientific research, food and beverage, and hydraulic systems. Paired with display instruments with special functions, it can also perform quantitative control, over limit alarm and other functions, making it an ideal instrument for flow measurement and energy conservation.
 

  • Features

1、High precision, generally up to ± 1% R, ± 0.5% R, and high-precision models up to ± 0.2% R;

2、Compact and lightweight structure, easy installation and maintenance, and high circulation capacity;

3、Adopting a hard alloy structure, suitable for wear-resistant types, preventing impeller jamming and increasing service life;

4、Wide range ratio, with a maximum range ratio of 1:20;

5、Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments;

6、Output pulse frequency, 4-20mA standard analog signal, suitable for total measurement and computer connection, no zero drift, strong anti-interference ability;

7、Large screen backlit LCD display, allowing clear and intuitive reading in darker environments;
 

  • Technical Specifications
Measuring medium
Impurity free, low viscosity liquid (viscosity range: ≤ 5mPa · s)
Flow range
0.25~1800m ³/h optional
Accuracy class
1%/ 0.5%/ 0.2% 
Accuracy
± 2% reading, ± 1%/full scale
Instrument caliber
(DN10~DN40)50/65/80/100/150/200/250/300
Shell material
Stainless steel 304/316
Install
flange connection
Atmospheric pressure 70KPa~106KPa
Power supply voltage
3.6V lithium battery/12-24V DC
Output method
Pulse signal/4-20mA
Installation direction
Horizontal and vertical (flow direction: from bottom to top)
Install straight pipe section
Upstream 20D, downstream 5D, except for regulating valves
Explosion-proof rating
Exd IIB T6 Gb
Protection level