
1. High accuracy, generally up to 1%R, 0.5%R, and up to 0.2%R for the high-accuracy type;
2. Compact and lightweight structure, easy installation and maintenance, large flow capacity;
3. PTFE optional, suitable for various acid and alkali liquids;
4. Wide rangeability, up to 1:20;
5. Suitable for high-pressure measurement; no hole is needed in the meter body, making it easy to build high-pressure meters;
6. Outputs pulse frequency, 4~20mA, RS485 optional; suitable for totalization and computer connection, with no zero drift and strong anti-interference capability;
7. Automatic data saving to prevent data loss;
8. Large backlit LCD display for clear, intuitive readings in dim environments;
| Measuring Medium | Highly corrosive liquid | Flow Range | 0.25~1800m³/h optional |
| Accuracy Class | 1%/ 0.5%/ 0.2% | Accuracy | ±2% of reading,±1% of full scale |
| Meter Diameter | (DN10~DN40) 50/65/80/100/150/200/250/300 | Housing Material | PTFE optional |
| Installation | Flange connection | Atmospheric Pressure | 70KPa~106KPa |
| Supply Voltage | 3.6V lithium battery / 12~24V DC | Output Mode | Pulse signal / 4~20mA / RS485 |
| Installation Method | Horizontal, vertical (flow direction: bottom to top) | Installation Straight Pipe Section | 20D upstream, 5D downstream, excluding control valves |
| Explosion-proof Class |
Exd II BT6
|
Protection Class | IP65 |