1. Suitable for measuring various single or mixed gases, and for installation in large-diameter circular, rectangular or square pipes;
2. Uses a platinum resistance temperature sensor with new patented technology;
3. Wide rangeability, extremely low minimum flow velocity;
4. High accuracy, good repeatability;
5. Low straight pipe requirements before and after installation: 5D upstream and 3D downstream is sufficient;
6. Independent of gas temperature and pressure, no temperature/pressure compensation required, directly measures gas mass flow;
7. Wide-screen LCD display for direct reading of instantaneous and cumulative flow;
8. Low overall power consumption; can be powered by internal batteries or an external power supply;
| Measuring Medium | Suitable for various single or mixed gases (dusty, sandy, humid and various corrosive gases) | Pipe Diameter Range |
DN10~DN300
|
| Flow Velocity Range | 0.1Nm/s~100Nm/s (standard conditions 20℃, 101.33kPa) | Accuracy | ±2% of reading,±1% of full scale |
| Repeatability | 0.2% of full scale | Rangeability | 100:1 (depending on the calibrated flow range) |
| Medium Temperature | -10℃~100℃ / -10℃~200℃ optional | Nominal Pressure |
≤4.0MPa
|
| Power Supply | 24VDC/600mA; 220VAC/2W; 110VAC/3W | Response Speed | 1S |
| Output | 4~20mA / RS232 / RS485 / alarm output | Flow Display | Large-screen LCD display |
| Alarm | 1~2 relay outputs, 5A/220V, 5A/30VDC, keypad settable | Protection Class | IP65 |
| Explosion-proof Class | Intrinsically safe / flameproof | Sensor Diameter | φ2.5, φ3. φ4 |
| Sensor Material | 316 stainless steel / Hastelloy / titanium | Installation Straight Pipe Section | 5D upstream, 3D downstream |
| Ambient Temperature | -40℃~85℃ (no display); -30℃~70℃ (with display); humidity below 90%RH | ||